Certified Pioneer Installer
Dripping Rainwater is a certified Pioneer Water Tanks installer in the Texas Hill Country. We install new Pioneer steel tanks and service existing ones, including liners, fittings, roofs and pads, whoever put them in.
The short answer
Dripping Rainwater is a certified Pioneer Water Tanks installer based in Dripping Springs, serving the Texas Hill Country. We install new Pioneer steel tanks with the pad, liner and roof built to Pioneer's specifications, and we service existing Pioneer tanks, including liner, fitting and roof repairs, no matter who installed them.
A Pioneer tank is a corrugated steel shell with a flexible liner holding the water and a steel roof on top. Most problems we see are at the liner, the fittings or the pad, not the steel itself. Pioneer publishes detailed pad and assembly requirements, and building to them protects both the tank and its warranty.
Before you call
Three things to check on an existing Pioneer tank before you call.
Look at the outlet fittings first. A slow weep at a bulkhead is far more common than a liner failure, and it's a much simpler repair.
Gaps in the roof, inlet or overflow screens let in light, insects and debris. That shows up later as sediment, odor or algae in the tank.
Erosion or settling under one side of the tank stresses the wall, liner and fittings. Fix the drainage before it becomes a leak.
How we diagnose it
What you see from outside a Pioneer tank usually points at what's happening inside it.
| What you're seeing | Usual cause | What it takes to fix |
|---|---|---|
| Level drops with the pump off | Fitting or liner leak | Check fittings first, then inspect the liner. Small damage can be patched; an aged liner is replaced inside the existing shell. |
| Water at the tank base | Bulkhead or outlet fitting | Reseal or replace the fitting and relieve any strain from the pipe run. |
| Debris, insects or algae in the tank | Roof gap or torn screens | Repair the roof seal and replace inlet and overflow screens. |
| Tank leaning or pad eroding | Drainage undermining the pad | Regrade and redirect overflow before the shell or liner is stressed. |
| Rust at the base of the shell | Soil or standing water against the steel | Clear the base and correct drainage so the steel stays dry. |
The visit
We check the pad for erosion and settling and see where the overflow and roof runoff are going.
Every penetration and fitting from outside, and the liner from inside where access allows.
Roof seal, inlet screen and overflow screen, the gaps that let debris and insects in.
You get what's fine, what's marginal and what needs work, with a price before anything starts.
Equipment
We install Pioneer tanks from about 5,000 to 97,000 gallons and service Pioneer tanks of any age.
Related
FAQ